CONFIDENTIAL [AK8999A/AW/AD]
MS1600-E-00 2014/05
- 23 -
7.2.9) SCF & SMF
VDD = 3, 3.3, 5V ± 10%, Ta = -40 to 105ºC, register default, unless otherwise note
Parameter Symbol Conditions Min. Typ. Max.
Units
Description
Measurement in test mode after offset voltage and span voltage adjustment
SCF&SMF
freq. response
Fc1 ESCF[1:0] = 1h
10Hz referenced -3dB
0.8 1.0 1.2 kHz
Fc2 ESCF[1:0] = 2h
10Hz referenced -3dB
400 500 600 Hz
Fc3 ESCF[1:0] = 3h
10Hz referenced -3dB
200 250 300 Hz
SCF&SMF
gain
SCFG1 ESCF[1:0] = 1h
1.000 1.111 1.222 times
7.2.10) External temperature sensor drive circuit
VDD = 3, 3.3, 5V ± 10%, Ta = -40 to 105ºC, register default, unless otherwise note
Parameter Symbol Conditions Min. Typ. Max.
Units
Description
Temp. sensor
sink current
Iconst1 After IREF adj.
45 50 55 μA
Temp. sensor
source current
Iconst2 After IREF adj.
ETMP[1:0] = 1h
-55 -50 -45 μA
Input voltage
range (sink)
Extpsi4 VS = 4V
3160 3400 3610 mV
Extpsi2 VS = 2.2V
1350 1600 1810 mV
Input voltage
range (surce)
Extpso ETMP[1:0] = 1h
392 600 866 mV